Limited operating inlet ambient temperature requirements
Limited operating inlet ambient temperature requirements
The maximum operating inlet ambient temperature value for most components installed in the server is 35°C (95°F). However,
installing some components in specific configurations are subject to temperature limitations. To ensure safe and reliable system
operation, identify the limited operating inlet ambient temperature required for these configurations.
In the following tables, the processor thermal design power (TDP) is set at a default value. Use the UEFI System Utilities to adjust the
TDP setting within preset limits—configurable TDP (cTDP).
From the System Utilities screen, select System Configuration > BIOS/Platform Configuration (RBSU) > Processor Options. Enter the
number in milliwatt (mW) for the Processor RAPL wattage value field.
Subtopics
Subtopics
Limited operating inlet ambient temperature requirements for DDR5 4800 256 GB DIMM
Limited operating inlet ambient temperature requirements for DDR5 4800 256 GB DIMM
Limited operating inlet ambient temperature requirements for HPE InfiniBand HDR100 / Ethernet 100GB 2-port QSFP56 PCIe4 x16
Limited operating inlet ambient temperature requirements for HPE InfiniBand HDR100 / Ethernet 100GB 2-port QSFP56 PCIe4 x16
Adapter
Adapter
Limited operating inlet ambient temperature requirements for HPE NS204i Boot Device
Limited operating inlet ambient temperature requirements for HPE NS204i Boot Device
Limited operating inlet ambient temperature requirements for DDR5 4800 256 GB DIMM
Limited operating inlet ambient temperature requirements for DDR5 4800 256 GB DIMM
The following temperature values are valid for all drive configurations.
Fan presence
Fan presence
Fan redundancy Maximum inlet ambient temperature
Fan redundancy
Fans 2–4
Not supported
Fans 1–4
Not supported
Fans 1–8
Supported
Limited operating inlet ambient temperature requirements for HPE
Limited operating inlet ambient temperature requirements for
Ethernet 100GB 2-port QSFP56 PCIe4 x16 Adapter
Ethernet 100GB 2-port QSFP56 PCIe4 x16 Adapter
AOC stands for active optical cable, while DAC stands for direct attach copper cable.
IMPORTANT:
IMPORTANT:
High-bandwidth HDR InfiniBand and Ethernet adapters might cause the fans to operate at high speeds to maintain
optimum system cooling. This high-speed fan operation can generate excessive fan noise and lead the system to be on
standby mode.
Drive configuration
Drive configuration
4 LFF / 8 SFF
8 LFF / 16 SFF
8 NVMe x4
Maximum inlet ambient temperature
25°C (77°F)
25°C (77°F)
30°C (86°F)
Cable type
Cable type
DAC
AOC
DAC
AOC
DAC
AOC
HPE InfiniBand HDR100 /
Processor TDP
Processor TDP
All
≤ 270 W
> 270 W
All
≤ 270 W
> 270 W
All
All
HPE ProLiant ML350 Gen11 Server User Guide
InfiniBand HDR100 /
Maximum inlet ambient
Maximum inlet ambient
temperature
temperature
30°C (86°F)
30°C (86°F)
25°C (77°F)
30°C (86°F)
30°C (86°F)
25°C (77°F)
30°C (86°F)
25°C (77°F)