15. Power up the server.
16. To configure the memory settings:
a. From the boot screen, press F9 F9 to access the UEFI System Utilities.
b. From the System Utilities screen, select System Configuration > BIOS/Platform Configuration (RBSU) > Memory Options.
Results
Results
The installation is complete.
Secondary riser cage and tertiary riser options
Secondary riser cage and tertiary riser options
The primary riser cage is default in the server. The server supports two secondary riser cage options and one tertiary riser option.
These secondary riser options use the same riser cage but have different riser boards:
PCIe5 4 x8 slots riser board
PCIe5 2 x16 slots riser board
The tertiary riser uses the PCIe5 2 x8 slots riser board.
Subtopics
Subtopics
Installing the secondary riser cage
Installing the secondary riser cage
Installing the tertiary riser
Installing the tertiary riser
Installing the secondary riser cage
Installing the secondary riser cage
Prerequisites
Prerequisites
If installing the secondary riser cage, make sure that the server is in a dual-processor configuration .
Before you perform this procedure, make sure that you have a T-10 Torx screwdriver available.
Procedure
Procedure
1. Power down the server.
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Disconnect all peripheral cables from the server.
4. Do one of the following:
If the server is in tower mode, place the server on a flat, level surface with the access panel facing up .
If the server is in rack mode, remove the server from the rack .
5. Remove the access panel .
6. Remove the secondary riser cage blank.
HPE ProLiant ML350 Gen11 Server User Guide
106