Bottom Cooking Chamber Sensor Defective (697, 729) - Henny Penny FlexFusion FPG-221 Service Instructions Manual

Gas platinum combi incl. grease collection
Table of Contents

Advertisement

Fault messages & troubleshooting

Bottom cooking chamber sensor defective (697, 729)

Check contacting from cooking chamber sensor to control board A1 X26. Error eliminated?
Remove existing cooking chamber sensor from the control board A1 X26 and plug in new cooking
Replace control board.
88
Description
Emergency operation is activated automatically and displayed.
Measurement of the cooking chamber temperature is done
exclusively by the top cooking chamber sensor.
Troubleshooting
chamber sensor. Error eliminated?
No
Alternatively, disconnect top cooking chamber sensor from A1 X25 for
test purposes and connect to A1 X26 to see if the error "migrates".
Service-instructions
Yes
Replace cooking chamber sensor.