Fault messages & troubleshooting

GAS_ID12: Gas error

GAS_ID13: Flame fault during operation

14.9 Testing the gas components

Checking the electrodes

a
X1
Neutral/Line
10
6
5
1
110V
110V
Preparations •
116
Description
The error message appears sporadically or continuously. The device
is no longer ready for operation.
Troubleshooting
Replace ignition module. Ensure that the plug on the ignition module
is undamaged.
Description
The error message appears sporadically or continuously.
Troubleshooting
If the error occurs again, replace the ignition module. If the error
persists, contact the manufacturer.
b
3 µA
F1 3,15A
a Ignition module A10 / A20
b Transformer T10 / T20
Glow electrode
Select and start the Gas CO
Do not start troubleshooting until Gas request lights up green.
Service-instructions
c
24-28V, ~1,4A
1-6 Ohm
c Ionization electrode (flame
monitoring) B100 / B200
d Glow electrode F10 / F20
calibration in the service menu.