12.3 Converting the gas type

DANGER
DANGER
DANGER
DANGER
6. Set the CO
content to the specified range for minimum output
2
using the adjustment screw behind the cap.
Turn the adjustment screw to the right to increase the CO
content.
Turn the adjustment screw to the left to reduce the CO
content.
7. Screw on the cap of the gas valve.
8. On models with two burners: Repeat the procedure for the second
burner.
9. Check the exhaust gas values.
10.Press the "Stop" button.
The burner is off.
Risk of personal injury and property damage from electric shock
• Before working on the unit, ensure that the unit has been disconnected from
the power supply.
Risk of explosion and fire from escaping gas
• When bleeding air from or degassing the gas system and the unit, ensure
that the air and gas are discharged to the outside in a technically correct
manner and without creating a risk.
Risk of explosion or fire from operating the unit with the wrong
gas type because of missing or incorrect gas type supplemental
label
• When converting to a different gas type, replace the gas type supplemental
label on the unit with the appropriate gas type supplemental label for the
gas type available.
Risk of personal injury and property damage from electric shock
• Inspection and adjustment work that can be carried out only with the hous-
ing open and the unit under power must be performed only by electrically
trained qualified personnel.