Smart Combi
Classic Combi
6.6.3 Display burner status and cooking chamber
Global Foodservice Solutions
temperature
1. Press Pre h e a t (1 0 ).
With tabletop units: Display (9) shows "GF".
With floor standing units: Display (9) shows "GF1" or "GF2".
With error-free burner ignition: Display (8) shows "00", "10", "11".
Display
6 F
6 F1
6 F2
00
10
11
If the gas supply is interrupted the ignition procedure will be aborted.
Display (9) flashes "Err" for errors.
Display (8) flashes the error number.
The Ste p ( 1 3 ) LEDs flash.
Planning and installation instructions
Meaning
Burner gas valve, flame sensor
Chamber 1: Burner gas valve, flame sensor
Chamber 2: Burner gas valve, flame sensor
Gas valve closed, no flame
Gas valve open, no flame (ignition)
Gas valve open, flame present (burner ignited)
Gas