Emergency Operation - Henny Penny FlexFusion FPG-221 Service Instructions Manual

Gas platinum combi incl. grease collection
Table of Contents

Advertisement

14.3 Emergency operation

Description
Description In order to allows limited use in case of error, the appliance has
INFORMATION
Overview
Upper chamber sensor faulty.
Lower chamber sensor faulty.
Vapour sensor defective
Internal core temperature sensor faulty. Cooking program was
canceled. Cooking program can be restarted after changing to
external core temperature sensor.
External core temperature sensor faulty. Cooking program
was canceled. Cooking program can be restarted after
changing to internal core temperature sensor.
various emergency programs. Emergency operation is activated
automatically and displayed. After elimination of the error indicated,
the controller switches back into regular operation automatically. A
reset is not necessary.
Emergency programs handle the limited further operation of the appliance until
servicing. Deviating cooking results and temperature deviations are possible.
Error
Service-instructions
Fault messages & troubleshooting
Description
Measurement of the cooking chamber
temperature is done exclusively by the
bottom cooking chamber sensor.
Measurement of the cooking chamber
temperature is done exclusively by the top
cooking chamber sensor.
The software controls the water vapor
elimination. This results in higher water
consumption.
The core temperature sensor is deactivated.
85