Henny Penny FlexFusion FPG-221 Service Instructions Manual page 28

Gas platinum combi incl. grease collection
Table of Contents

Advertisement

Service menu - appliance test
28
Step 4 (steam generation)
1. Check of DynaSteam² steam generation.
Display switches to green = test successful.
Display switches to red = test not successful.
Ensure that water is being supplied on-site.
Check of DynaSteam steaming.
Check of water supply pipe for calcification.
Step 5 (steam reduction)
1. Check of steam reduction (lift magnet).
Display switches to green = test successful.
Display switches to red = test not successful.
Check of lift magnet via relay test. A fault is present on the
component or the control board. Check associated fuses.
Step 6 (WaveClean circulation pump)
1. Check of WaveClean circulation pump.
Display switches to green = test successful.
Display switches to red = test not successful. Test 7 and 8 are
not evaluated.
Check of circulation pump via relay test. A fault is present on the
component or the control board. Check the fuse on the control
board.
Step 7 (water supply to WaveClean)
1. Check of solenoid valve for steam elimination.
Display switches to green = test successful.
Display switches to red = test not successful.
Ensure that water is being supplied on-site.
Check of solenoid valve via relay test. A fault is present on the
component or the control board. Check the fuse on the control
board.
Step 8 (WaveClean siphon pump)
1. Check of WaveClean siphon pump.
Display switches to green = test successful.
Display switches to red = test not successful.
Check of siphon pump via relay test. A fault is present on the
component or the control board. Check the fuse on the control
board.
Service-instructions