Henny Penny FlexFusion FPG-221 Service Instructions Manual page 67

Gas platinum combi incl. grease collection
Table of Contents

Advertisement

Check and adjust exhaust gas values
d
a
b
c
Image: Exhaust gas measurement
a Exhaust gas measuring device
c Waste gas connection, burner 2
(size 2XX only)
High power (full load)
Checking the exhaust gas values
1. CO2 settings (via password "999" or in the service menu).
2. Set "Output" field to high output ("High").
3. On models with two burners, select the "Cooking zone 1" field for
burner 1.
4. Press the "Start" button.
The burner status "Gas request" appears in green.
The burner status "Flame detected" appears in green.
Unit is operated at high power (full load).
5. Measure the CO
2
exhaust gas measuring device in the exhaust pipe at operating
temperature.
The temperature in the cooking chamber is displayed in green.
To regulate the cooking chamber temperature, open the
cooking chamber door slightly.
6. Check whether the measured CO content is within the specified
range.
If CO content is not within the specified range, adjust basic gas
setting (see "Adjusting exhaust gas values (CO
7. On models with two burners: Repeat the procedure for the second
burner.
Service-instructions
b Waste gas connection, burner 1
d Steam outlet nozzle
content of the exhaust gases with an approved
Gas technology
setting)").
2
67