Siphon temperature very high (SOF_ID20, ID21)
Description The temperature in the siphon is >100°C. The water vapor sensor B4
Prerequisite Water supply available on-site at both water connections.
Troubleshooting
Risk of frost (TMP_ID72, MMI_ID51)
is used for the measurement.
Update software to version 1.71 or higher. As of this version the
fault is ignored.
Fill the siphon with 2 liters of water from inside the cooking
chamber.
Check the solenoid valve for steam elimination K12 via the relay
test.
Perform the WaveClean test.
Description
The unit is not ready for use. The temperature sensor on the control
board is measuring a temperature of <0°C.
Troubleshooting
Increase the room temperature and switch on unit again.
Change location of the unit.
Service-instructions
Fault messages & troubleshooting
91