Internal Core Temperature Sensor Lower Cooking Chamber; Cooking Chamber Sensor And Protective Basket Upper And Lower Cooking Chamber - Henny Penny FlexFusion ELECTRIC SPACESAVER PLUS TEAM Maintenance Manual

Hide thumbs Also See for FlexFusion ELECTRIC SPACESAVER PLUS TEAM:
Table of Contents

Advertisement

8.4.6 Internal core temperature sensor lower cooking chamber

Check internal core temperature sensor for damage
Test criteria
• Core temperature sensor is not bent or damaged.
If No
Change core temperature sensor.
Check tight fit of internal core temperature sensor
Test criteria
• Screw connection of the internal core temperature sen-
sor is tightened.
If no
Tighten the screw connection.
8.4.7 Cooking chamber sensor and protective basket upper and lower cooking
chamber
CAUTION
Check cooking chamber sensor and protective basket for damage
Test criteria
• Protective basket is not bent or damaged.
• Cooking chamber sensor is not damaged.
• The cooking chamber sensor is bent slightly upwards.
If No
Replace protective basket.
Replace cooking chamber sensor.
Check the cooking chamber sensor and protective basket for contamination
Test criteria
• Protective basket is not dirty or calcified.
• Cooking chamber sensor is not dirty or calcified.
If No
Clean the cooking chamber sensor and protective basket.
Fire hazard due to overheating of the unit
Deposits can falsify the measurement result of the temperature sensor and
cooking results can deviate from the ideal.
• Only operate unit with a clean temperature sensor.
• Clean the temperature sensor and the protective basket.
ð If cleaning does not produce the desired result or is not feasible, the
temperature sensor must be replaced.
Maintenance instructions
Performing maintenance
Remarks / values
Remarks / values
Remarks / values
Remarks / values
Yes
No
Yes
No
Yes
No
Yes
No