14.4 Temperature sensor area

Cooking chamber sensor defective (694, 695)

Check contacting from cooking chamber sensor to control board A1 X25. Error eliminated?
Remove existing cooking chamber sensor from the control board A1 X25 and plug in new cooking
Replace control board.
86
Description
Emergency operation is activated automatically and displayed. The
core temperature sensor takes over the function of the cooking
chamber sensor. Cooking program with core temperature sensor is
no longer available.
Troubleshooting
chamber sensor. Error eliminated?
No
Service-instructions
Yes
Replace cooking chamber sensor.