Henny Penny FlexFusion FPG-221 Service Instructions Manual page 73

Gas platinum combi incl. grease collection
Table of Contents

Advertisement

DANGER
WARNING
Risk of explosion and fire from escaping gas
• When bleeding air from or degassing the gas system and the unit, ensure
that the air and gas are discharged to the outside in a technically correct
manner and without creating a risk.
Check for leaks outside the unit.
Risk of poisoning from exhaust gases
• Ensure that exhaust gases are discharged properly and that the necessary
amount of combustion air is supplied.
• Ensure that a maximum CO content of < 0.1 vol. % or < 1000 ppm is
achieved in undiluted exhaust gas.
Switch on the unit.
Check for leaks inside the unit.
Make CO
settings.
2
Switch off unit and attach side wall.
Valid from S/N 16212356
Gas Orifices CSA
Unit size
Gas orifice natural
gas
(Gas A)
615
115
215
621
121
221
Service-instructions
Gas orifice liquid gas
(Gas E)
680
590
590
590
580
580
Gas technology
470
420
420
430
400
400