Fault messages & troubleshooting

No gas (top)(OTH_ID2)

No gas (bottom)(OTH_ID3)

No flame (OTH_ID4)

No flame (top)(OTH_ID5)

112
Description
The error message appears if there was no response to the first gas
request when the program was started.
For floor standing units, the error refers to the upper burner.
Troubleshooting
Troubleshooting as for error message No gas
Description
The error message appears if there was no response to the first gas
request when the program was started.
For floor standing units, the error refers to the lower burner.
Troubleshooting
Troubleshooting as for error message No gas
Description
The error message appears if the flame was detected during the first
gas request at program start (feedback from ionization electrode
present) and then lost again (no feedback from ionization electrode).
Troubleshooting
Troubleshooting as for error message No gas
Description
The error message appears if the flame was detected during the first
gas request at program start (feedback from ionization electrode
present) and then lost again (no feedback from ionization electrode).
For floor standing units, the error refers to the upper burner.
Troubleshooting
Troubleshooting as for error message No gas