Fault messages & troubleshooting

Communication fault between I/O and ignition module (OTH_ID25)

Replace CAN bus cable between control board, connector X4 and ignition module. Error

Communication fault between I/O and ignition module (top)(OTH_ID26)

Replace CAN bus cable between control board, connector X4 and ignition module. Error
114
Description
There is a communication fault between the control board and ignition
module.
Troubleshooting
eliminated?
No
Replace ignition module. Error eliminated?
No
Replace control board.
Description
There is a communication fault between the control board and ignition
module for the upper burner.
Troubleshooting
eliminated?
No
Replace ignition module. Error eliminated?
No
Replace control board.