Performing maintenance

8.5.3 Internal core temperature sensor

Check internal core temperature sensor for damage
Test criteria
• Core temperature sensor is not bent or damaged.
If No
Change core temperature sensor.

8.5.4 Cooking chamber sensor and protective basket

CAUTION
Check the cooking chamber sensor and protective basket for contamination
Test criteria
• Protective basket is not dirty or calcified.
• Cooking chamber sensor is not dirty or calcified.
If No
Clean the cooking chamber sensor and protective basket.
Check cooking chamber sensor and protective basket for damage
Test criteria
• Protective basket is not bent or damaged.
• Cooking chamber sensor is not damaged.
• The cooking chamber sensor is bent slightly upwards.
If No
Replace protective basket.
Replace cooking chamber sensor.

8.5.5 Fan wheel, heating element and water inlet

Check heating element and fan wheel for limescale residues
Test criteria
• Heating element is free of limescale residues.
• Fan wheel is free of limescale residues.
If No
Decalcify the unit.
28
Fire hazard due to overheating of the unit
Deposits can falsify the measurement result of the temperature sensor and
cooking results can deviate from the ideal.
• Only operate unit with a clean temperature sensor.
• Clean the temperature sensor and the protective basket.
ð If cleaning does not produce the desired result or is not feasible, the
temperature sensor must be replaced.