Configuration Of The Control Board - Henny Penny FlexFusion FPG-221 Service Instructions Manual

Gas platinum combi incl. grease collection
Table of Contents

Advertisement

Electronics

11.3 Configuration of the control board

Connector X1
Connector X2 Not in use
Connector X3 Digital ignition module for lower system
Connector X4 Digital ignition module for upper system
Connector X5 CAN bus line to upper motor M1
Connector X6 CAN bus line to lower motor M2
Connector X7 MMI communication
Connector X8 Digital key contains device-specific information.
Connector X9 (24V DC)
Connector X10 (120V AC)
Connector X11 (120V AC) Not in use
Connector X12 (208V AC)
Connector X13 Not in use
Connector X14 (potential
Connector X15 (120V AC)
60
No.
1
Input 10.7 V AC for lighting
2
3/4
Power supply I/O board 18V AC
No.
1/2
Supply for control panel (MMI)
No.
1
Supply voltage for relay
2
Output K1, main contactor Q1
3
-
4/5
N
No.
1
Output K17, WaveClean pump G16
2
-
3
Output K4, solenoid valve K12
4
Output K5, siphon pump G24
5
Output K6, backup relay
6
-
7
N
No.
free)
1
Input K11, cooling fan G7, G8, G9 (120V AC)
2
Output K11, cooling fan G7, G8, G9 (120V AC)
No.
1
Input K13, supply line from fuse F1