Dynasteam Test - Henny Penny FlexFusion FPG-221 Service Instructions Manual

Gas platinum combi incl. grease collection
Table of Contents

Advertisement

Service menu - appliance test

7.8 DynaSteam test

Description The DynaSteam test allows a function test of DynaSteam steaming.
Prerequisite
Overview
Starting the test
INFORMATION
36
Calibration is not possible / necessary.
Access to the water supply pipe in the cooking chamber.
Left hooking-in point or tray trolley removed.
Air baffle in the cooking chamber unlocked and unfolded.
Touch "Initialization" field.
Automatic pre-rinse.
Field changes to "START".
Set water quantity using the rollers.
Touch the "START" field.
Activation of the DynaSteam steaming unit.
The water comes runs from the water supply pipe into the
cooking chamber.
Collect the water from the supply pipe with a measuring container.
Starting water test.
After the predetermined amount of water has gone through,
activation stops automatically.
Compare amount of water with the set value. A deviation of +-
10% is within tolerance.
Dual-chamber units (20.x) have two DynaSteam steaming units with parallel
control. The specified quantity of water refers to one chamber. Perform Dy-
naSteam test for each chamber separately.
Service-instructions