FAN_ID23: Fan error: Attempt to restart

Replace communication cable between motor control and motor for test purposes and perform test
Check the output voltage at connector X2 between terminals 1 and 2. Is a voltage of approx.
No voltage present. Replace power board for motor.

FAN_ID24: Upper fan fault: Attempt to restart

FAN_ID25: Lower fan fault: Attempt to restart

Description
The control board A1 does not receive any response regarding speed
from fan motor M10. There is either a problem with the 320 V voltage
supply from the power board or a fault in the fan.
Troubleshooting
Switch off unit and restart. Is the fault still present?
run. Switch unit on "I." Error eliminated?
320 V DC present?
No
Description
The control board A1 does not receive any response regarding speed
from upper fan motor M10. There is either a problem with the 320 V
voltage supply from the power board or a fault in the fan.
Troubleshooting
See "FAN_ID23: Fan error: Try restarting".
Description
The control board A1 does not receive any response regarding speed
from lower fan motor M20. There is either a problem with the 320 V
voltage supply from the power board or a fault in the fan.
Service-instructions
Fault messages & troubleshooting
Yes
No
Yes
Voltage present. Replace fan motor.