7.24 Backup relay

Description The control board has a spare relay, which allows alternative use in
Locate defective relay
Occupying the spare relay
INFORMATION
Overview
Assigning the backup relay
Canceling the selection Touch the "Back" field.
Relay overview
Relay
Connect
or
K1
X10
K1
X11
K2
X11
K4
X12
K5
X12
K6
X12
K8
X17
case of a relay failure. This is only possible with the listed relays.
Call relay test in the service menu.
Perform relay test. Locate defective relay by examining the
output voltage at the corresponding outputs on the control
circuit board.
Do rewiring according to the table.
Example: When using it for K8 (lift magnet M8), rewire line from
connector X17.1 to X12.5.
In case of changes to the wiring, label or deposit note in the unit.
Select the defective relay by means of the roller.
Touch the "OK" field.
Changes saved.
No.
Description
2
Main contactor Q1
1
POS A
2
POS B
3
Solenoid valve for vapor
quenching K12
4
Siphon pump G24
5
Backup relay K6
1
Lift magnet fresh air M8
Service-instructions
Service menu - appliance test
Instruction
Re-connect the line from X10. 2 to X12. 5 and to
assign a reserve relay to it.
Re-connect the line from X11.1 to X12.5 and to
assign a reserve relay to it.
Re-connect the line from X11. 2 to X12. 5 and to
assign a reserve relay to it.
Re-connect the line from X12.3 to X12.5 and to
assign a reserve relay to it.
Re-connect the line from X12.4 to X12.5 and to
assign a reserve relay to it.
Re-connect the line from X12.5 to X12.5 and to
assign a reserve relay to it.
Re-connect the line from X17.1 to X12.5 and to
assign a reserve relay to it.
43