4.6.2 Core temperature standard setting

4.6.3 Cooking chamber humidity standard setting

4.7 Basic settings

Basic setting
Password
Start time selection
with or without fan
Steam elimination
Displays
Unit of temperature
24
The adjustment range for the core temperature depends on the cooking
mode.
Cooking mode
Steaming
Combisteaming
Hot air
Regeneration
Cooking chamber humidity setting range depends on the cooking
mode.
Cooking mode
Steaming
Combisteaming
Convection
Regeneration
The unit is delivered with presets. The values in the following list can be
modified in the parameter level.
Parameter
Standard
s
value
7
111
13
0
48
1
1
0
Operating instructions
Standard value
Setting range
(°C (°F))
(°C (°F))
70 (158 )
0 (32 ) - 99
(210,2 )
70 (158 )
0 (32 ) - 99
(210,2 )
70 (158 )
0 (32 ) - 99
(210,2 )
50 (122 )
0 (32 ) - 99
(210,2 )
Standard value
Setting range
(%)
(%)
100
90 - 110
90
20 - 100
100
0 - 100
100
0 - 100
Range of
Explanation
adjustment
0 — 300
The password for the basic settings can be
changed in this range.
0 = Without fan
If the "0" setting is selected, the fan
remains off during the preset time period.
1 = With fan
If the "1" setting is selected, the fan runs at
intervals during the preset time period.
0 = Low
Sets the steam elimination level
1 = Normal
2 = High
0 = °C
Celsius (°C)
1 = °F
Fahrenheit (°F)
Change increments
(°C (°F))
1 (33,8 )
1 (33,8 )
1 (33,8 )
1 (33,8 )
Change increments
(%)
90 - 100 - 110
20 - 40 - 70 - 90 - 100
0 - 25 - 50 - 75 - 100
0 - 25 - 50 - 75 - 100