Co2 Setting - Henny Penny FlexFusion FPG-221 Service Instructions Manual

Gas platinum combi incl. grease collection
Table of Contents

Advertisement

12.2 CO2 setting

Notes on safety
DANGER
WARNING
Opening the Setting menu
DANGER
WARNING
INFORMATION
Prerequisite Gas connection line connected
Risk of personal injury and property damage from electric shock
• Inspection and adjustment work that can be carried out only with the hous-
ing open and the unit under power must be performed only by electrically
trained qualified personnel.
Risk of poisoning from exhaust gases
• Ensure that exhaust gases are discharged properly and that the necessary
amount of combustion air is supplied.
• Ensure that a maximum CO content of < 0.1 vol. % or < 1000 ppm is
achieved in undiluted exhaust gas.
Risk of personal injury and property damage from electric shock
• Inspection and adjustment work that can be carried out only with the hous-
ing open and the unit under power must be performed only by electrically
trained qualified personnel.
Risk of poisoning from exhaust gases
• Ensure that exhaust gases are discharged properly and that the necessary
amount of combustion air is supplied.
• Ensure that a maximum CO content of < 0.1 vol. % or < 1000 ppm is
achieved in undiluted exhaust gas.
Some measurements on the unit require it to be at opeating temperature.
• The operating temperature is reached when the temperature in the cooking
chamber is between 130 °C —180 °C.
Checked for leaktightness outside the unit
Connection pressure checked
Checked for leaktightness inside the unit
Left side wall removed
1. Check the rated heat input at maximum output.
2. Check the rated heat input at minimum output.
Service-instructions
Gas technology
65

Advertisement

Table of Contents
loading

Table of Contents