Fault messages & troubleshooting

Failure to access external EEPROM (SOF_ID12)

Faulty CAN connection

5007: Not enough storage space for software update

5008: No new version found

106
Description
It is not possible to access the digital key (EEPROM).
Troubleshooting
Make sure that the digital key is oriented correctly and inserted
fully. The side with the hole must point to the sensor connections.
Control board defective.
Digital key defective.
Description
There is a communication fault between the operating panel and
control panel. In addition, temperature sensor and fan fault messages
appear on the touchscreen.
Troubleshooting
Replace communication cable between operating panel and
control panel circuit board.
Replace control board.
Replace operating panel.
Description
The internal memory is full. The current version will be restarted. The
cause can be faulty data import (additional content).
Troubleshooting
Replace operating panel. Alternatively, continue to operate with
the current software.
Send the operating pane to the manufacturer for repair.
Description
The following causes generate the message:
USB stick not recognized or not present
Required content not present on the USB stick or saved incorrectly.
The software version on the unit is newer than that on the USB stick.
Service-instructions