Henny Penny FlexFusion FPG-221 Service Instructions Manual page 83

Gas platinum combi incl. grease collection
Table of Contents

Advertisement

No.
Fault message displayed
GAS_ID13
Flame fault during operation
ID18
Excess temperature in the cooking chamber
ID73
MMI_ID50
Critical temperature in the electronics
OTH_ID1
No gas
OTH_ID2
No gas (top)
OTH_ID3
No gas (bottom)
OTH_ID4
No flame
OTH_ID5
No flame (top)
OTH_ID6
No flame (bottom)
OTH_ID7
Error gas blower
OTH_ID8
Error gas blower (top)
OTH_ID9
Error gas blower (bottom)
OTH_ID25
Communication fault between I/O and ignition
module
OTH_ID26
Communication fault between I/O and ignition
module (top)
OTH_ID27
Communication fault between I/O and ignition
module (bottom)
SOF_ID12
Failure to access external EEPROM
SOF_ID20
Siphon temperature very high
SOF_ID21
TMP_ID2
Overtemperature in control
TMP_ID72
Risk of frost
MMI_ID51
Faulty CAN connection
Unit was restarted after power failure
Door is open - cooking program was stopped
Fault messages & troubleshooting
Section
GAS_ID13: Flame fault during operation
Excess temperature in the cooking chamber
(ID18, ID73)
Critical temperature in the electronics (MMI_ID50)
No gas (OTH_ID1)
No gas (top)(OTH_ID2)
No gas (bottom)(OTH_ID3)
No flame (OTH_ID4)
No flame (top)(OTH_ID5)
No flame (bottom)(OTH_ID6)
Communication fault between I/O and ignition
module (OTH_ID25)
Communication fault between I/O and ignition
module (top)(OTH_ID26)
Communication fault between I/O and ignition
module (bottom) (OTH_ID27)
Failure to access external EEPROM (SOF_ID12)
Siphon temperature very high (SOF_ID20, ID21)
Overtemperature control (TMP_ID2)
Risk of frost (TMP_ID72, MMI_ID51)
Faulty CAN connection
Unit was restarted after power failure
Door is open - cooking program was stopped
Service-instructions
83

Advertisement

Table of Contents
loading

Table of Contents