7.4 CombiDoctor

Description The CombiDoctor offers an automatic check of the climate control
Overview
Selecting a program
Starting the program
Evaluation
and the WaveClean automatic cleaning. The tests are possible
individually or as overall test. For instructions on performing, see the
touchscreen.
Select a program by adjusting the roller.
Touch the "START" field.
The test result appears on the touchscreen.
Entry in HACCP memory.
Step 1 (test door contact)
1. Open cooking chamber door and close again.
If test successful, proceed with the next test step.
If the door is not recognized as having been opened and
closed again within the specified time (60 seconds), the test is
not passed.
Step 2 (prepare for WaveClean)
1. Preparation for WaveClean test.
Automatic water exchange via the siphon pump and the solenoid
valve for steam elimination.
Step 3 (heat output)
1. Check of heat output.
Display switches to green = test successful.
Display switches to red = test not successful.
Check of on-site voltage supply.
Check of heating element for electric energy type
Check of semiconductor relay for electric energy type
Check of ignition process for gas energy type
Check of internal fuse for load circuit (depends on unit version).
Service-instructions
Service menu - appliance test
27