Solenoid valve flushing

INFORMATION
Switch on solenoid valve K41 via relay test (K14) in
the service menu. After approx. 30 seconds,
additionally switch on grease pump G40 in the relay
test (K13). Is water pumped into the collection tank?
Ensure that water is being supplied on-site. Is this
available?
Are 120V available at the solenoid valve?
Solenoid valve K41 defective. Replace component.
Nature and source of danger
Install backflush fitting on grease drain hose before testing.
Before checking the solenoid valve, make sure that the grease pump is
working properly.
No
Yes
Yes
Service-instructions
Fault messages & troubleshooting
Yes
There is no error
No
Carry out troubleshooting on the on-site supply.
No
Relay on control board A1 defective. Use reserve
relay or replace circuit board.