Send Data With 0, If Ignition Is Off (Id=1601); Fma110 With Lv-Can200 And All-Can300 Can Adapters; Purpose Of Can Adapters Lv-Can200 And All-Can300; Can200 And All-Can300 Program Number Selection - Teltonika FMA110 User Manual

Table of Contents

Advertisement

8.8.2

Send data with 0, if ignition is off (ID=1601)

This parameter enables/disables data sending with 0 value, if ignition is off. 0 – disable, 1-
enable.
Minimum
Maximum
value
value
0
1

9 FMA110 with LV-CAN200 and ALL-CAN300 Can Adapters

9.1

Purpose of Can Adapters LV-CAN200 and ALL-CAN300

LV-CAN200 is used to listening data from light vehicles, while
data from any type of transport: light vehicles, Trucks, busses, agriculture and other special transport.
With those adapters FMA110 device is able to collect and send vehicle data.
FMA110 shares the same USB port for connecting adapter and configuring device with PC.
LV-CAN200 and ALL-CAN300 Technical characteristics:
9.2
LV-CAN200 and ALL-CAN300 program number selection
LV-CAN200 or ALL-CAN300 must be set to program number which depends on
vehicle model. Needed program number is always written on LV-CAN200 or ALL-CAN300
mounting scheme. Please contact Your Teltonika sales manager to get latest supported
Recommended
value
1
ALL-CAN300
LV-CAN200
PC
Figure 53 connection block diagram
PARAMETER
Supply voltage
Power supply current
Working temperature
Max working humidity 60 % (non condensate)
Goes with (depends on)
parameters
ALL-CAN300 is used to listening
U
FMA110
SB
USB Cable
U
FMA110
SB
VALUE
9 to 50V
Average 10mA
Max (peak) 100mA
-40..85 ºC
Value
type
U8