Static Navigation (Id=1003); Ignition Source (Id=1004); Ignition Detection (Id=1920); Ignition Detection Timeout (Id=1921) - Teltonika FMA110 User Manual

Table of Contents

Advertisement

8.2.5

Static Navigation (ID=1003)

When static navigation is enabled, FMA110 filters out GPS jumps, when it is not moving.
When it is disabled, it does not make any changes to collected GPS data.
Minimum
Maximum
value
value
0
1
8.2.6

Ignition source (ID=1004)

Device can operate and change its working mode according to motion detection source:
Power Voltage (value 0), Digital Input 1 (value 1), movement (value 2).
Minimum
Maximum
value
value
0
2
8.2.7

Ignition detection (ID=1920)

If ignition source is Power voltage device can operate in 2 different ignition detection
regimes - Manual (value 0) and Auto (value 1). In manual regime power voltage high and power
voltage low levels need to be set. In auto regime device automatically detects system voltage (6V,
12V or 24V) and detects ignition according default voltage ranges.
Minimum
Maximum
value
value
0
1
8.2.8

Ignition detection timeout (ID=1921)

When ignition source is selected as Power Voltage and Ignition detection is set as auto,
ignition timeout need to be set.
Minimum
Maximum
value
value
0
65536
Recommended
Goes with (depends on)
value
1
Recommended
Goes with (depends on)
value
Ignition detection timeout
-
Power Voltage High Level
Recommended
Goes with (depends on)
value
-
Ignition detection timeout
Recommended
Goes with (depends on)
value
10
parameters
parameters
Ignition detection
(ID=1920)
(ID=1921)
(ID=1005)
Power Voltage Low Level
(ID=1006)
parameters
Ignition source
(ID=1004)
(ID=1921)
parameters
Ignition source
(ID=1004)
Ignition detection
(ID=1920)
Value
type
U8
Value
type
U8
Value
type
U8
Value
type
U8
63

Advertisement

Table of Contents
loading

Table of Contents