Communication; Addressing - HBM DMP41 Interface Description

Digital precision measuring device
Hide thumbs Also See for DMP41:
Table of Contents

Advertisement

Command set of the HBM interpreter

Communication

CHS
30
5.2
Communication
5.2.1

Addressing

Control character (only with RS‐232‐C):
CTRL R:
Start of computer communication
(ASCII code 18 decimal)
CTRL B:
Start of computer communication
(ASCII code 2 decimal)
Channel Select
Select amplifier channel
Syntax:
CHS p1(x)
Parameter:
p1
p1
Channel encoding value
1 - 63
Channel combinations are set by the sum of the corresponding channel
encoding values.
DMP41-T6
Channel encoding value p1
1
2
4
8
16
32
63
DMP41-T2
Channel encoding value p1
1
2
3
A03474_04_E00_00 HBM: public
Channel number
1
2
3
4
5
6
All
Channel number
1
2
All
DMP41

Advertisement

Table of Contents
loading

Table of Contents