HBM DMP41 Interface Description page 63

Digital precision measuring device
Hide thumbs Also See for DMP41:
Table of Contents

Advertisement

MEV
DMP41
#14ffeedd00(y)
y
ASCII format
x
z
z:
Identifier for binary output
x:
Indicates the number of decimal places of y (x=0 with con­
tinuous output)
y:
Indicates the number of binary bytes that follow (omitted in
continuous output)
E.g.:
x = 1
y = 8 (8 binary bytes are output)
x = 2
y =16 (16 binary bytes are output)
Measuring Extended Values Query
Output of extended measured values
Syntax:
MEV? p1 (x)
Parameter:
p1
Selection of amplifier signal
p1
Channel mask for temperature values (up to 4, also for
1
2
4
8
...
15
The maximum sampling rate is 1 Hz; it is reduced as the
number of temperature sensors connected increases (1Hz/
n). The temperature is returned in
The status of the temperature channel is transmitted by
another parameter.
A03474_04_E00_00 HBM: public
Command set of the HBM interpreter
1 byte status
3 byte measured value
DMP41−T2)
Temperature 1
Temperature 2
Temperature 3
Temperature 4
All temperature sensors
o
C x 100.
Amplifier functions
Binary format