HBM DMP41 Interface Description page 65

Digital precision measuring device
Hide thumbs Also See for DMP41:
Table of Contents

Advertisement

TEX?
DMP41
Parameter:
p1
Parameter separator
Default: 44, ASCII ","
p2
Block separator
Default: 13, ASCII "CR"
Effect:
ASCII characters entered with p1 and p2 act as separators
in ASCII measured value output (command MSV?). ASCII
characters entered with p1 are output as parameter separa­
tors, ASCII characters entered with p2 are output as block
separators between repeated measured values.
Response:
Acknowledge-
ment
0
Command executed
?
Example:
TEX59,13(x)
0(y)
59
13
Define Terminator Query
Output measured value separator
Syntax:
TEX?(x)
Parameter:
none
Effect:
Output measured value separator (see TEX).
Response:
q1,q2(y)
Parameter and block separator
Example:
TEX?(x)
44,13(y)
44
13
A03474_04_E00_00 HBM: public
Command set of the HBM interpreter
1 - 126
1 - 126
Significance
Error
ASCII ";"
ASCII "CR"
ASCII ","
ASCII "CR"
Amplifier functions
65

Advertisement

Table of Contents
loading

Table of Contents