User Manual of Thermal Network Positioning system
2. Check the checkboxes of the interface to set the temperature measurement
configurations.
Enable Temperature Measurement: Check the checkbox to enable temperature
measurement function.
Enable Color-Temperature: Check the checkbox to display Temperature-Color
Ruler in live view.
Display Temperature Info. on Stream: Check the checkbox to display temperature
information in live view.
Add Original Data on Capture: Check the checkbox to add original data on capture.
Add Original Data on Stream: Check the checkbox to add original data on stream.
Data Refresh Interval: Select the data refresh interval from 1s to 5s.
Unit: Display temperature with Degree Celsius (° C)/Degree Fahrenheit (° F)/Degree
Kelvin (K).
Temperature Range: Set the temperature range.
Emissivity: Set the emissivity of your target. Note: The emissivity of each object is
different.
Distance (m): The straight-line distance between the target and the device.
3. Clcik Save to save the settings .
© Hikvision
Figure 5-25 Dynamic Fire Source Detection
59