CV3100 series and MINI series high performance general purpose inverter instruction manual
t1: actual jog acceleration time;t3: actual jog deceleration time;
t2: Jog running time;f1: jog running frequency.
Note: P2.20,P2.21 is the accel.& decel time when jog frequency is equal to basic
frequency (50Hz), however the factory setting of jog frequency is10 Hz, so calculating
according to this proportion, the actual accel. & decel. time shall be set as 20% of
factory setting value. In addition, the jog running command can be realized by keypad,
external terminals or PC input.
P2.22
Accel. time 2
P2.23
Decel. time 2
P2.24
Accel. time 3
P2.25
Decel. time 3
P2.26
Accel. time 4
P2.27
Decel. time 4
Setting range
Please refer to P3.09 for the setting of above parameters.
The above parameter set the accel and deccel.time of 2,3,4 respectively.
Accel. & decel. time 1、2、3、4 all can selected by control terminals,and as the accel
and deccel.time during inverter running. The function of terminals is determined by
the choice of P4.00-P4.05.
P2.28
The 1st step freq.
P2.29
The 2nd step freq.
P2.30
The 3rd step freq.
P2.31
The 4th step freq.
P2.32
The 5th step freq.
P2.33
The 6th step freq.
P2.34
The 7th step freq.
P2.35
Reserved
Setting range
They are used to define the frequency for multi-step speed running from step 1 to7.
Please refer to P7.00 for details.
Determined by inverter type
Determined by inverter type
Determined by inverter type
Determined by inverter type
Determined by inverter type
Determined by inverter type
0.1-3600s
0.00-Upper limit frequency
6-22
Factory setting
Factory setting
Factory setting
Factory setting
Factory setting
Factory setting
Factory setting
5.00Hz
10.00Hz
15.00Hz
20.00Hz
25.00Hz
30.00Hz
40.00Hz