CV3100 series and MINI series high performance general purpose inverter instruction manual
reducing noise and load concussion during accelerating and decelerating process.
Parameter for S-curve is determined by P2.06 and P2.07.
Output frequency
P2.06 P2.07
Diagram 6-7 S-curve accel. & decel.
P2.06
S-curve starting duration proportion
Setting range
P2.07
S-curve ascend/descend duration proportion
Setting range
S-curve staring stage, shown as ① in Diagram 6-7, is the process that slope of
frequency output gradually increases from zero; S-curve ascending stage, shown as ②
in Diagram 6-7,is the process that slope of frequency output keeps invariable.
It specially apply for transmission and carrier loads with combination use of above
parameter
P2.08
AVR function
using of
Setting range
the
above
0: Inhibitive
paramet
1: Allowable
ers is
more
suitable
10.0—40.0%
10.0—40.0%
0
Inhibitive
1
Allowable
6-17
time
Factory setting
Factory setting
Factory setting
20.0%
60.0%
1