CV3100 series and MINI series high performance general purpose inverter instruction manual
Analog output width or pulse output frequency is positively proportional to inverter
output current.
AO1:(0- AO1 upper limit)~(0.0- twice rated current)
DO3:(0- DO3 upper limit)~(0.0-twice rated current)
3:Motor rev.
Analog output width or pulse output frequency is positively proportional to motor rev.
AO1:(0- AO1 upper limit)~(0- motor synchronous speed)
DO3:(0- DO3 upper limit)~(0- motor synchronous speed)
4:Output voltage
Analog output width or pulse output frequency is positively proportional to inverter
output voltage.
AO1:(0- AO1 upper limit)~(0-maximum/rated output voltage)
DO3:(0- DO3 upper limit)~(0-maximum/rated output voltage)
5:Bus voltage
Analog output width or pulse output frequency is positively proportional to inverter
bus voltage.
AO1:(0- AO1 upper limit)~(0-800V)
DO3:(0- DO3 upper limit)~(0-800V)
6:PID ration
Analog output width or pulse output frequency is positively proportional to PID ration.
AO1:(0- AO1 upper limit)~(0.00-10.00V)
DO3:(0- DO3 upper limit)~(0.00-10.00V)
7:PID feedback
Analog output width or pulse output frequency is positively proportional to PID
feedback.
AO1:(0- AO1 upper limit)~(0.00-10.00V)
DO3:(0- DO3 upper limit)~(0.00-10.00V)
P5.11
AO1 gain setting
Setting range
P5.13
DO3 gain setting
Setting range
P5.12
Reserved
P5.14
Reserved
P5.11 defines the upper limit output of AO1. When the factory setting is 100%, the
20—200%
20—200%
6-39
Factory setting
Factory setting
100%
100%