High performance general purpose inverter
Table of Contents

Advertisement

CV3100 series and MINI series high performance general purpose inverter instruction manual
The following list may be more intuitive, but meaning unchanged:
STX
Address
Function
DATA(n-1)
......
DATA 0
CRC CHK Low
CRC CHK High
END
The specific meaning of the format is as following:
Address:communication, 0 ~ 31 (decimal)
00H : Broadcast address. information frame sent by broadcast
address,slave machine will no response.
01H ~ 1FH:to a specific address drive.
Function:function code,also call command byte,there are 127 function
code in Modbus communication ,now we only use three of them,detail as
follow:
03H:Readout the content of register
06H:Write a date into register
10H:Write many data into register
DATA(n-1):specific data, will have the application example as below.
RTU mode check code(CRC Check),detail introduction refer to the last
page。
Keep no input signal is equal or more than
10 ms
The communication address: 8-bit binary
address
Function code: 8-bit binary address
Data content:
N * 8-bit material, n < = 2 (two 16 bit data)
CRC check code:
16-bit CRC check code by two 8-bit binary
combination
Keep no input signal is equal or more than
10 ms
9-3