P6.13
Sleeping threshold
Setting range
This parameter defines inverter feedback limit from working status to sleeping status.
If the feedback value is more than the setting value, when the inverter output
frequency drops to low limit frequency after the delay time of P6.15,then the
inverter go into sleeping.(0 rotate speed running)
P6.14
Waking threshold
Setting range
P6.15
Sleep/Wake waiting time
Setting range
P6.14 parameter defines inverter feedback limit from sleeping status to working
status,P6.15 parameter defines the transferring time between sleep and wake status. If
the feedback value is less than the setting value, the inverter will wake up from
sleeping status after P6.15 waiting delay time and start to run again.
Sleeping threshold
PID setting
Waking threshold
Output frequency
Lower limit
frequency
0.0—10.00V
0.0—10.00V
0.1—600.0S
P6.15
Diagram 6-25 Sleeping & waking function
Factory setting
Factory setting
Factory setting
PID feedback
sleeping
P6.15
6-48
10.00V
0.00V
300.0S
waking