CV3100 series and MINI series high performance general purpose inverter instruction manual
Function
Name &
Code
Definition
Stage 5
P7.05
running
time
Stage 6
P7.06
running
time
Stage 7
P7.07
running
time
P7.08
Reserved
Multi-step
speed
P7.09
running
direction 1
Multi-step
speed
P7.10
running
direction 2
Set Range
0.0~6000.0s
0.0~6000.0s
0.0~6000.0s
LED single digit:Stage 1
direction
0:Forward
1:Reverse
LED tens digit:Stage 2 direction
0:Forward
1:Reverse
LED hundreds digit:Stage 3
direction
0:Forward
1:Reverse
LED thousands digit:Stage 4
direction
0:Forward
1:Reverse
LED single digit:Stage 5
direction
0:Forward
1:Reverse
LED tens digit:Stage 6 direction
0:Forward
1:Reverse
LED hundreds digit:Stage 7
direction
0:Forward
1:Reverse
LED thousands digit:
Reserved
5-13
Communic
Minimun
Factory
Unit
Default
0.1s
10.0s
0.1s
10.0s
0.1s
10.0s
1
0000
1
000
ation
Modify
Address
0705H
0706H
0707H
0709H
070AH