Function
Name &
Code
Definition
Wobbling
frequency
P7.11
running
mode
Wobbling
P7.12
pre-setting
frequency
Wobbling
presetting
P7.13
frequency
waiting
time
Wobbling
P7.14
frequency
width
Skip
P7.15
frequency
Wobbling
P7.16
freq. period
Triangle
P7.17
wave
risetime
Norm of
central
P7.18
wobbling
frequency
Set Range
LED single digit:Reserved
LED tens digit:Wobbling range
control
0:Fixed
1:Variable
LED hundreds digit:
Selection of wobbling frequency
start up mode after power off
0:Start up according to memory
before stop
1:Restart
LED thousands digit:
Selection of Wobbling frequency
status storage after power off
0:Storing after power off
1:Not storing
0.00Hz~Upper limit freq.
0.0~3600.0s
0.0~50.0%
0.0~50.0%(relate to wobbling
frequency range)
0.1~3600.0s
0.0~100.0%(Wobbling period)
0.00Hz~Upper limit feq.
5-14
Communic
Minimun
Factory
Unit
Default
1
000
0.01Hz
10.00Hz
0.1s
0.0s
0.1%
10.0%
0.1%
10.0%
0.1s
10.0s
0.1%
50.0%
0.01Hz
10.00Hz
ation
Modify
Address
070BH
×
070CH
070DH
×
070EH
070FH
0710H
0711H
0712H