CV3100 series and MINI series high performance general purpose inverter instruction manual
A&V
Hz&A&V
RUN
REV/JOG
STOP/RESE
T
PRG
Key
function
SET
▲ /▼
The operation mode of the keyboard and switch state
According to different display content and receive instruction, there are 5 different
working mode.
① Status monitoring mode
This is normal working mode. Under any circumstance, if there is no any key input
for 1 minute, the keypad panel will recur to this mode automatically.
② Monitoring examining mode
Under this mode, press
output frequency, output current and so on. d-00 is the defaulted parameters for
monitoring by system. Choose function parameter P3.04,P3.05 to monitor other
parameters for a long time.
When the LED display content is liner velocity, the two lights is on
at the same time
When the LED display content is temperature, the three lights is on
at the same time
Run key: Inverter operation instruction of channel control mode is
set to the panel([P0.04=0]), enter into run mode under keyboard
mode.
Inverter
acceleration/deceleration curve to the rated power.
Jog/ Reverse key:This function is decided by parameter P0.23 When
P0.23=0, reverse running.When P0.23=1, Jog running.
Stop/Reset key:In common run status the inverter will stop
according to set mode after this key is pressed if run command
channel is set as panel effective mode([P0.04=0]). The inverter will
reset and resume normal stop status after this key is pressed when
the inverter is in malfunction status.
Mode switch key:Used to change the operation mode of the
operation panel.When press this button, control panel will enter
parameters query mode to query operation parameters. Press this
button again to parameters modification mode.
Confirm key:confirm the current stage or parameters storage(store
into internal storage)
Data modification keys: Used to modify data function code or
parameters.In condition monitoring mode, if the specified frequency
channel is set to the panel digital set mode[P0.01=1], press this key
instructions directly modifying frequency values
Shift/Monitor key:Choose the digit of the data which is to be set and
modified when the inverter is in edition status; switch monitor
parameter to be shown when the inverter is in other statuses. In
condition monitoring mode, directly press this button to parameter
query mode which could cycling show the content of d-00~d-28.
Note: this query method will firstly display monitor code, 2 seconds
later for detailed contents.
Diagram 4-1
▲ /▼ key to choose the state of data, such as output voltage,
4-6
runs
according
to
the
specified