a1
RUN
Diagram 6-28 Holding ultimate value after single circulation
4:Wobbling frequency running
The inverter output frequency varies periodically within accel & decel time preset.
It mainly applies for the system, such as textile of synthetic fibre machine of which
speed changes according to different diameter in the front and the back of tubeshown
as Diagram 6-29:
Stage 1 running time
P7.01
P7.02
Stage 2 running time
P7.03
Stage 3 running time
P7.04
Stage 4 running time
P7.05
Stage 5 running time
P7.06
Stage 6 running time
P7.07
Stage 7 running time
Reserved
P7.08
Setting range
P7.09
Multi-step speed running dirction 1
P7.10
Multi-step speed running dirction 2
Setting range
These above parameters are used for providing the running time, running direction and
acceleration & deceleration time of simple programmable multi-step speed, which are
f2
a2
f1
d3
a3 f3
a4
T1
T2
T3
0.0—6000.0s
0000—1111(0:Rotation 1:Reverse)
f6
d7 f7
a6
f5
a5
d5
f4
T4
T5
T6
Factory setting
Factory setting
Factory setting
Factory setting
Factory setting
Factory setting
Factory setting
Factory setting
Factory setting
6-51
T7
10.0s
10.0s
10.0s
10.0s
10.0s
10.0s
10.0s
0000
-000