EasyDrive CV3100 Series Instruction Manual page 58

High performance general purpose inverter
Table of Contents

Advertisement

CV3100 series and MINI series high performance general purpose inverter instruction manual
Function
Name &
Code
Definition
FWD/REV
terminal
P4.06
control
method
Open
collector
P4.07
terminal DO1
output
Open
collector
P4.08
terminal DO2
output
Programmabl
P4.09
e relay output
FDT level
P4.10
setting
P4.11
FDT lag value
Freq. arrival
P4.12
FAR checkout
width
Overload
P4.13
pre-alarm
checkout level
Overload
P4.14
pre-alarm
delayed time
Counter reset
P4.15
value
Counter
P4.16
checkout
value
Set Range
0: Two-line control mode 1
1: Two-line control mode 2
2: Three-line control mode 1
3: Three-line control mode 2
(reserved)
0: Inverter running indication
1: Freq./speed arrival signal
(FAR)
2: Freq./speed detecting signal
(FDT)
3: Inverter zero speed running
indication
4: Peripheral failure stop
5: Output freq. arriving at the
upper limit
6: Output freq. arriving at the
lower limit
7: Programmable multi-step
speed circular running finished
8: Inverter overload alarming
signal
9: Inverter starts to run in train
10:Counter checkout signal
output
11:Counter reset signal output
12: Inverter failure
13:less-voltage stopping
14: Wobbling frequency
fluctuationlimit
15: Programmable multi-step
speed running finished.
16: Reserved
17: Timing to output
0.00Hz~Upper limit frequency
0.0~30.00Hz
0.00Hz~15.0Hz
20~120%
0.0~15.0s
【P4.16】~60000
0~【P4.15】
5-8
Communi
Minimun
Factory
Unit
Default
1
0
1
0
1
1
1
12
0.01Hz
10.00Hz
0.1Hz
1.00Hz
0.01Hz
5.00Hz
1%
100%
0.1s
1.0s
1
1
1
1
cation
Modify
Address
0406H
×
0407H
0408H
0409H
040AH
040BH
040CH
040DH
040EH
×
040FH
×
0410H
×