Shown as following diagram, DO1 is defined as reset signal output, DO2 is defined as
checkout signal output, P4.15 is set to ―8‖, and P4.16 is set to ―5‖.
When the checkout value is equal to ―5‖, DO2 will send out collector open signal and
keep on; when the reset value is equal to ―8‖, DO1 will send out collector open signal
and reset the counter, at the same time DO1, DO2 will cancel signal output.
1
DI6
DO1
DO2
Diagram 6-18 Counter rest value and counter checkout value setting
6.6 Analog input and output parameter
P5.00
AI1 input voltage of lower limit
Setting range
P5.01
AI1 input voltage of upper limit
Setting range
The above parameters define the range of analog voltage input channel AI1, which
shall be set according to actual input signal.
P5.02
AI2 input current of lower limit
Setting range
P5.03
AI2 input current of upper limit
Setting range
The above parameters define the range of analog voltage input channel AI2, which
shall be set according to actual input signal.
2
3
4
0.0—F5.01
P5.00—10.0V
0.0—P5.03
P5.02—20.0mA
6-36
5
6
7
Factory setting
Factory setting
Factory setting
Factory setting
8
9
0.0V
10.0V
0.0mA
20.0mA