EasyDrive CV3100 Series Instruction Manual page 108

High performance general purpose inverter
Table of Contents

Advertisement

CV3100 series and MINI series high performance general purpose inverter instruction manual
output voltage & current range is 0-10V & 0-20mA. The analog voltage or current
output is decided by jumper terminal JP2.
AO1 output=(0-10V/0-20mA)× AO1 gain setting(not more than 10V/20 mA)
P5.13 defines the upper limit output of DO3. When the factory setting is 100%, the
output frequency range is 0-10KHz.
DO3 output=(0-10 KHz)× DO3 gain setting (not more than 20 KHz)
P5.15
Compounding given channel setting
Setting range
LED single digit: Operand 1
0:Keypad potentiometer;
1:Digital setting 1
2:reserved
3:Communication setting
4:AI1
5:AI2
6:Terminal pulse
LED tens digit:Operand 2
0:Keyboard potentiometer
1:Digital setting 1
2:Reserved
3:Communication setting
4:AI1
5:AI2
6:Terminal pulse
LED Hundreds digit:Operand 3
0:Keyboard potentiometer
1:Digital setting 1
2:Reserved
3:Communication setting
4:AI1
5:AI2
6:Terminal pulse
LED Thousands digit: Reserved
000—666
6-40
Factory setting
000

Hide quick links: