CV3100 series and MINI series high performance general purpose inverter instruction manual
Function code explain in detail and communication frame sample:
03H:Readout the content of register
Readout binary data from slave machine holding register,no support
broadcast, At present a frame information can read a maximum of 5 address
continuous data.
Query message frame format:
Slave address + 03H + register address + the register number of data hold(N) +
CRC CHK
|
|
|
|
|
|
|_____________________________________________length:1byte :
|
|________________________________________________________length:1byte
Slave address
Function code
Register address
Register number ( N)
CRC check code
|
|
|____________________________________length:2byte
1~31(decimal)
03H
Address high 8-bit
Address low 8-bit
high 8-bit
low 8-bit
low 8-bit
high 8-bit
9-4
|
|___________________length:2byte
1byte
1byte
2byte
2byte
2byte
Note:check code low 8-bite
ahead
|__length: 2byte