EasyDrive CV3100 Series Instruction Manual page 153

High performance general purpose inverter
Table of Contents

Advertisement

CV3100 series and MINI series high performance general purpose inverter instruction manual
For example
(Ⅰ)Write in starting forward command and its running frequency given
1088H(continuous running) to the address 1FH slave machine
Query the frame:
Response the frame:
The first address of parameter
Address
Function
The first address of
parameter
Data volume(word)
Data volume(Byte)
Drive command
Given frequency value
CRC CHK Low
CRC CHK High
Address
Function
data volume(word)
CRC CHK Low
CRC CHK High
1FH
10H
20H
00H
00H
02H
04H
00H
1EH
10H
88H
67H
E6H
1FH
10H
20H
00H
00H
02H
49H
B6H
9-19