CV3100 series and MINI series high performance general purpose inverter instruction manual
6.9 Communication parameter
P8.00
Local communication address
Setting range
This parameter is used to identify the address when the inverter is set to RS485
communication, the address is unique.
0:Master station
It means the inverter is used as master when serial port communicates, to control the
running of the other connected inverters.
1-31:Slave station
It means the inverter is used as slave to receive the data from PC or master station.The
inverter only received the data form PC or master in accordance with the address
marked.
P8.01
Communication scheme
Setting range
This parameter defines the RS485 communication baud rate. In order to normal
communication, all relative communication parties must be set the same baud rate and
prescribed the same communication data format.
LED single digit:Baud rate settin
1:2400BPS
2:4800BPS
3:9600BPS
4:19200BPS
5:38400BPS
LED tens digit:Data format
0:No checkout
1:Even checkout
2:Odd checkout
LED hundreds digit:Reserved
LED thousands digit:
0:Feedback information when modifying parameters
1:No feedback information when modifying parameters
P8.02
Communicating overtime checkout time
Setting range
0—31
0000—0125
0.0-100.0s
6-55
Factory setting
Factory setting
Factory setting
1
013
10.0s