EasyDrive CV3100 Series Instruction Manual page 21

High performance general purpose inverter
Table of Contents

Advertisement

CV3100 series and MINI series high performance general purpose inverter instruction manual
communication way and connected by one 8-core network cable, the connection of
port is provided with RJ45 network interface connection, it is very convenient to
install. The max electric distance can reach as high as 50m. The remote-control
keyboard has following functions:
1)Can control the running, stopping, jogging, fault resetting, change of setting
frequency, change of function parameter and running direction of slave.
(2)
Can monitor operating frequency, setting frequency, output voltage, output
current and so on.
2.5.2 Communication cable
Communication cable of remote-control keyboard
Model
CV3100-LAN0020 (2.0m)
Among the specifications, 1m, 2m, 5m, 10m and 20m are standard configuration of
our inverter, if over 20m cables are is needed, please contact us. Be used for
connection between remote operating keyboard and master of inverter
2.5.3 Braking resistor
As CV3100 series inverter braking unit is option, if need, please indicate clearly when
ordering. Energy-consumption braking resistor is provided as shown in table 2-4, and
the installation of braking resistor wire is provided as shown in 2-3
Diagram 2-3 Connection between inverter and braking unit(Below 380V 18.5
U
R
S
inverter
V
T
W
PB
P
BRAKING
RESISTOR
KW)
2-12
.
M

Hide quick links:

Advertisement

Table of Contents
loading