⑭Mold Close Delay
MdClos : Mold Close Delay
Robot can delay the mold close, after taking out the parts from the mold, ascent, until traverse
movement to set position . Default setting is "NoUse". Position can be set in the range of No
Down Range.
Display
NoUse
No mold close Delay function.
(=Default)
Mold will close after robot arm ascent.
Mold will not close until the robot
Use
move to traverse position ( mm )
MdClos
Flee
Pitch
Swivel
Description
NoUse
NoUse
NoUse
Swivel
TSα Series User Manual 55
4. Operation
Motion
Mold Close Delay
Mold Close Delay
Distance ( mm )