Hard disk drive (HDD) / solid state disk (SSD)
Preliminary steps
▶
"Locating the defective server" on page
▶ If applicable,
"Removing the front cover with lock" on page
▶
"Shutting down the server" on page
▶
"Disconnecting the power cord" on page
▶
"Getting access to the component" on page
▶
"Removing the fan cage" on page
▶ Release all HDD modules and pull them out a few centimeters, see
"Removing a 3.5-inch HDD module" on page
CAUTION
The HDD modules need not to be removed.
▶
If you want to remove them nevertheless, check if all HDD
modules are uniquely identified so that you can reinsert them
into their original bays.
▶ Release all dummy modules and pull them out a few centimeters, see
"Removing a 3.5-inch HDD dummy module" on page
Removing the defective 12x 3.5-inch HDD backplane
▶ If applicable, remove the SAS expander board holder, see
SAS expander board holder" on page
▶ Remove the internal RAID riser module, see
riser module" on page
▶ Disconnect all cables from the HDD backplane.
156
52.
74.
209.
273.
Upgrade and Maintenance Manual
49.
53.
56.
149.
146.
"Removing the internal RAID
52.
"Removing the
RX2540 M6